T15-C Tri-Clamp Flush Diaphragm Pressure Transmitter
Tri-clamp flush diaphragm pressure transmitter; -100 kPa to 10 MPa, 0.5 % FS, up to 250 °C with cooling fins, IP65.
T15 is a pressure transmitter whose flush diaphragm design suits viscous media or media that may leave deposits. It is available for gauge, absolute and sealed gauge pressure with various output signal options.
| Pressure range | -100 kPa … 0 kPa ~ 10 kPa … 100 MPa |
|---|---|
| Overpressure limit | ≤ 1.5 × FS or minimum 110 MPa (whichever is lower) |
| Pressure type | Gauge / Absolute / Sealed gauge |
| Process connection | M20×1.5 male with sealing (other connections on request) |
| Accuracy | ≤ ±0.5 % FS (optional: 0.2 % or 0.1 %) |
| Long-term stability | ≤ ±0.3 % FS/year |
| Zero temperature drift | ≤ ±0.05 % FS/°C (≤100 kPa); ≤ ±0.03 % FS/°C (>100 kPa) |
| Span temperature drift | ≤ ±0.05 % FS/°C (≤100 kPa); ≤ ±0.03 % FS/°C (>100 kPa) |
| Compensated temperature | 0 ~ 50 °C |
| Operating temperature | -30 ~ 80 °C; -10 ~ 60 °C (Exia); -20 ~ 60 °C (Exd); -10 ~ 70 °C (cable type) |
| Storage temperature | -40 ~ 120 °C; -20 ~ 85 °C (cable type) |
| Supply voltage | 11 V ~ 28 V DC or 3.3 V / 5 V DC |
| Output signal | 4 mA ~ 20 mA DC (2-wire); 0/1 ~ 5/10 V DC (3-wire); 0.5 V ~ 2.5 V / 4.5 V DC (3-wire) |
| Load capacity | ≤ (U-11)/0.02 Ω (2-wire); ≥ 10 kΩ (3-wire) |
| Protection class | IP65 |
| Electrical connection | DIN 43650 plug or 1.5 m cable |
Tri-clamp flush diaphragm pressure transmitter; -100 kPa to 10 MPa, 0.5 % FS, up to 250 °C with cooling fins, IP65.
OEM pressure transmitter with SS304 body, SS316 diaphragm and G¼" male thread; 0.5 % FS accuracy, -10…+90 °C, IP65.
Pressure transmitter with SS304 body, SS316 diaphragm and G¼" male thread; 0.5 % FS accuracy, -10…+90 °C, IP65.