WB Series Block Valve
2/2 block valve preventing unexpected depressurisation of a cylinder chamber; G 1/8 – G 1/2, 0–10 bar, 500–1900 Nl/min, uni- and bi-directional.
XVF4 is a 3/2 N.C. amplifier valve that turns low-pressure signals into 1–8 bar pneumatic signals, while XVF5 is a 3/2 N.O. version turning negative (vacuum) signals into 1–7 bar signals. Both pilot UDS and UK valves directly with the same mounting as UL solenoid valves; XVB sub-bases serve single mounting and ULP bases manifold mounting.
| Operating pressure | XVF4: 1 – 8 bar; XVF5: 1 – 7 bar |
|---|---|
| Piloting pressure | XVF4: 500 mbar; XVF5: -500 mbar |
| Maximum frequency | 50 Hz |
| Flow rate (6 bar) | 500 Nl/min |
| Controlled leakage consumption | 1.4 Nl/min (7 bar) |
| Piloting hole | M5 |
| Type | Function | Actuation | Response time pilot / return (ms) | Flow at 6 bar ΔP=1 bar (Nl/min) | Weight (g) |
|---|---|---|---|---|---|
| XVF4 | 3/2 N.C. | Pneumatic | 26.64 / 38.42 | 500 | 10.5 |
| XVF5 | 3/2 N.O. | Vacuum | 21.14 / 32.66 | 500 | 10.5 |
2/2 block valve preventing unexpected depressurisation of a cylinder chamber; G 1/8 – G 1/2, 0–10 bar, 500–1900 Nl/min, uni- and bi-directional.
Precision uni-/bi-directional (URG/URF), standard in-line (URE) and silenced exhaust (URS) flow regulators; G 1/8 – G 1/2, 0–12 bar.
Shuttle valve conveying air from two different lines into one; G 1/8 – G 1/2, 0–12 bar, 700–5000 Nl/min.
Quick exhaust valve venting the working port directly to exhaust; G 1/4 – G 3/4, 0–12 bar, exhaust flow 2300–6000 Nl/min.