VPF/3/EP Pressure-Compensated 3-Way Fixed Flow Priority Divider
VPF/3/EP 3-way fixed flow priority valve; 1/2" – 3/4" ports, max. 210 bar.
Product code: VDFR
VDFR in-line spool-type flow divider/combiner; 3/8" – 1" ports, flow ranges from 4–12 to 90–150 l/min, 210 bar.
VDFR is a pressure-compensated spool-type flow divider that splits the inlet flow into two outlets according to the divide ratio and combines them in the reverse direction; pressure differences at the outlets do not affect the split. Max. pressure is 210 bar with aluminium and 350 bar with steel body; its cartridge equivalent is the PD type.
| Port size | 3/8" – 1" |
|---|---|
| Max. flow | 4 – 150 l/min (range by type) |
| Max. operating pressure | 210 bar |
| Body pressure rating | Aluminium 210 bar, steel 350 bar |
| Catalogue max. flow | 250 l/min |
| Type | Port size | Flow (l/min) | Max. pressure (bar) |
|---|---|---|---|
| VDFR 38/12 | 3/8" | 4-12 | 210 |
| VDFR 38/24 | 3/8" | 12-24 | 210 |
| VDFR 12/40 | 1/2" | 24-40 | 210 |
| VDFR 34/90 | 3/4" | 40-90 | 210 |
| VDFR 100/150 | 1" | 90-150 | 210 |
VPF/3/EP 3-way fixed flow priority valve; 1/2" – 3/4" ports, max. 210 bar.
VPF/3/EP+VMP 3-way fixed flow divider with relief valve; 3/8" – 1/2" ports, max. 210 bar.
VPR/3/EP 3-way adjustable priority flow regulator; 3/8" – 1 1/4" ports, max. 210 bar.
VPR/3/EP/VMP+VE and /LPD; 3-way flow regulators with relief valve and solenoid cut-off, 450 l/min, 350 bar; LPD for hydraulic hammers.