Cartridge Check Valves
NG8–NG30 M-SR cartridge (insert) check valves; 35–400 L/min, 315 bar, 0.5 bar cracking pressure.
Product code: CV-201 … CV-208
CV-201 to CV-208 hydraulic inline check valves; 1/4" to 2" thread sizes, working pressures up to 250–400 bar.
Oxim hydraulic check valves allow oil to flow freely in one direction and block flow in the reverse direction. Pilot-operated (load-holding) models block reverse flow until pressure is applied to the pilot line, so that cylinders hold their position under load and the load cannot lower by itself.
The range includes in-line check valves, slip-in cartridge check valves, in-line, sub-plate and sandwich-type pilot-operated check valves, and TLV series twin pilot-operated check (dual lock) valves; size, flow and pressure values are given in the tables.
CV-201 to CV-208 hydraulic inline check valves; 1/4" to 2" thread sizes, working pressures up to 250–400 bar.
| Model | Thread Size | Pressure (bar) | Description |
|---|---|---|---|
| CV-201 | 1/4" | 05-400 | Inline check valve |
| CV-202 | 3/8" | 05-400 | Inline check valve |
| CV-203 | 1/2" | 05-350 | Inline check valve |
| CV-204 | 3/4" | 05-350 | Inline check valve |
| CV-205 | 1" | 05-350 | Inline check valve |
| CV-206 | 1 1/4" | 05-250 | Inline check valve |
| CV-207 | 1 1/2" | 05-250 | Inline check valve |
| CV-208 | 2" | 05-250 | Inline check valve |
NG8–NG30 M-SR cartridge (insert) check valves; 35–400 L/min, 315 bar, 0.5 bar cracking pressure.
NG16 and NG22-25 Z2S sandwich-plate pilot-operated check valves; 200–360 L/min, 315 bar, 2.5 bar cracking pressure.
1/2"–1 1/2" in-line SV/SL pilot-operated check valves; 120–500 L/min, 315 bar, with or without drain line.
1/2"–1 1/2" subplate SV/SL pilot-operated check valves; 120–500 L/min, 315 bar, with or without drain line.