EDG-01 Proportional Pilot Relief Valve
Electro-hydraulic proportional pilot relief valve; NG6 (CETOP 3), 1/4" valve size, 2 l/min, 250 bar (catalogue) / 210 bar (EDG-01-H-20).
Product code: HNC
Electronic amplifier cards for proportional valves; HNC-1085 pressure (0–850 mA), HNC-4075 flow (0–750 mA), 0–9 V control input, ramp setting.
HNC-1085 drives pressure control valves (EDG, EBG) and HNC-4075 drives flow control valves. They convert a 0–9 V control voltage into proportional solenoid current; ramp-up and ramp-down times are adjustable between 0.1 and 2.5 s.
| Control input | 0 V ~ +9 V |
|---|---|
| Max. output current | 0–850 mA (HNC-1085), 0–750 mA (HNC-4075) |
| Power supply | AC 28 V ± 20% (HNC-1085), AC 40 V ± 20% (HNC-4075) |
| Ramp time | 0.1 – 2.5 s |
| Max. power | 15 VA / 40 VA |
| Ambient temperature | 0 – 50 °C |
| Feature | HNC-1085 | HNC-4075 |
|---|---|---|
| Use | Pressure card | Flow card |
| Power supply | AC 28V ±20% | AC 40V±20% |
| Fuse | 2A | 2A |
| Coil load resistance | 10Ω/20°C (68°F) | 40Ω/20°C (68°F) |
| Input control voltage | 0V~+9V | 0V~+9V |
| Max. output current range | 0-850 mA | 0-750 mA |
| Adjustable pilot current range | 0-150 mA | 0-150 mA |
| Ramp-up time | 0.1-2.5 sec | 0.1-2.5 sec |
| Ramp-down time | 0.1-2.5 sec | 0.1-2.5 sec |
| Temperature drift | 0.1 mA/C | 0.2 mA/C |
| Max. ambient temperature | 0-50°C (32-122°F) | 0-50°C (32-122°F) |
| Max. power requirement | 15 VA | 40 VA |
Electro-hydraulic proportional pilot relief valve; NG6 (CETOP 3), 1/4" valve size, 2 l/min, 250 bar (catalogue) / 210 bar (EDG-01-H-20).
Electro-hydraulic proportional relief valve; NG16, NG25 and NG32 (3/8" – 1 1/4"), 100–400 l/min, 200 bar (catalogue) / 210 bar (H-20).
P-Q valve combining proportional pressure and flow control in one body; NG16–NG32, 125–500 l/min, 200 or 250 bar, internal or external pilot.