TMR4 Thermostat with Power Relay
Fixed-setting thermostat with built-in power relay; 40–110 °C switching value, 30 A contact load, 24 V DC coil, IP67, max. 200 bar.
Product code: TF4-TM4-TM6-TS4
Fixed-setting bimetallic thermostats; 40–120 °C switching values, ± 3.5 °C accuracy, 1/2" BSP, 3/8" BSP or M22x1.5, max. 200 bar.
TF4, TM4 and TM6 thermostats open or close an electrical contact when a fixed temperature is reached; the TS4 series provides a changeover contact. They have brass bodies; the TM4 DIN connector can be rotated by 60°, and on TF4 the bimetallic sensor is resin-embedded in the body.
| Switching value | 40 – 120 °C (fixed) |
|---|---|
| Max. pressure | 200 bar |
| Switching accuracy | ± 3.5 °C |
| Hysteresis | ~ 6 °C |
| Connection | 1/2" BSP, 3/8" BSP, M22x1.5 male |
| Body | Brass; TF4/TM4/TS4 hex 27, TM6 square 30 |
| Contact load | TF4/TM4/TM6: 15 A / 125 V AC, 10 A / 12 V DC; TS4: 3 A / 125 V AC |
| Protection | IP00 (TF4), IP54 (with P1), IP65 (TM4, TM6, TS4) |
| Working temperature | -20 °C … +120 °C |
| TF4 | TM4 | TM6 | TS4 | Fixed switching value (°C) | Max. pressure (bar) |
|---|---|---|---|---|---|
| TF44 | TM44 | TM64 | TS44 | 40 | 200 |
| TF45 | TM45 | TM65 | TS45 | 50 | 200 |
| TF46 | TM46 | TM66 | TS46 | 60 | 200 |
| TF47 | TM47 | TM67 | TS47 | 70 | 200 |
| TF48 | TM48 | TM68 | TS48 | 80 | 200 |
| TF49 | TM49 | TM69 | - | 90 | 200 |
| TF49.0 | TM49.0 | TM69.0 | - | 100 | 200 |
| TF49.1 | TM49.1 | TM69.1 | - | 110 | 200 |
| - | TM49.2 | TM69.2 | - | 120 | 200 |
Fixed-setting thermostat with built-in power relay; 40–110 °C switching value, 30 A contact load, 24 V DC coil, IP67, max. 200 bar.
Thermostat driving fan motors directly with soft start; TMS4 fixed 40–90 °C, TMS5 25–90 °C speed control, 25 A / 24 V, IP67.
Fan motor thermostat with speed control; 10–90 °C setting range, soft start, timed reverse rotation program, 25 A, 12–24 V DC.
Electronic thermostat set by potentiometer; 40–90 °C setting range, changeover contact, ± 3% accuracy, 1/2" BSP, max. 100 bar.