CRE Cartridge Type Direct Operated Proportional Pressure Control Valve
D-10A seat cartridge proportional pressure control valve; 350 bar on P, 1.5 l/min max. flow, three control ranges up to 250 bar.
Product code: PRED3J
Closed loop ISO 4401-03 proportional pressure valve with pressure transducer feedback; 350 bar, 3 l/min, hysteresis < 1%.
PRED3J is a direct operated proportional pressure control valve with integrated electronics for closed loop pressure control and ISO 4401 interface. The value detected by the pressure transducer can be monitored on pin F; three adjustment ranges are available up to 350 bar.
| Mounting interface | ISO 4401-03 |
|---|---|
| Max. pressure (P / T) | 350 / 2 bar |
| Nominal / max. flow | 1 / 3 l/min |
| Reference signal | E0: 0–10 V, E1: 4–20 mA |
| Hysteresis | < 1% of p nom |
| Repeatability | < ±0.5% of p nom |
| Mass | 2.5 kg |
| Code | Control range |
|---|---|
| 140 | 1.1 - 140 bar |
| 210 | 1.8 - 210 bar |
| 350 | 2.8 - 350 bar |
| Type | Description | Max. pressure (bar) | Max. flow (l/min) | Voltage (V) |
|---|---|---|---|---|
| PRED3J-350/11N E1 | NG 6 proportional pressure relief with feedback and integrated card | 350 | 5 | 24 |
D-10A seat cartridge proportional pressure control valve; 350 bar on P, 1.5 l/min max. flow, three control ranges up to 250 bar.
ISO 4401-03 direct operated proportional pressure valve; 350 bar, 1 l/min nominal, 3 l/min max. flow, four ranges up to 350 bar.
ISO 4401-03 proportional pressure valve with integral digital electronics; 350 bar, 3 l/min, 0–10 V or 4–20 mA command, hysteresis < 3%.
ISO 4401-03 pilot operated proportional pressure control valve; 350 bar, 40 l/min max. flow, four control ranges up to 350 bar.