CHM2 NG4 Modular Pilot Operated Check Valve
ISO 4401-02 (NG4) modular hydraulically released check valve locking line A, B or A-B; 320 bar, 30 l/min.
Product code: MVR
ISO 4401-03 (NG6) modular check valve on P, A, B, T, P-T or A-B lines; 350 bar, 50 l/min, 0.5 / 3 / 5 bar cracking.
MVR is a modular direct check valve used to prevent backflow and self-emptying of lines, or to generate backpressure. It mounts under ISO 4401-03 solenoid valves without pipes, with single or dual line versions.
| Mounting interface | ISO 4401-03 (NG6) |
|---|---|
| Max. operating pressure | 350 bar |
| Max. flow (controlled lines) | 50 l/min |
| Max. flow (free lines) | 75 l/min |
| Cracking pressure | 0.5 / 3 / 5 bar |
| Mass | 1 kg |
| Type | Controlled line | Size | Max. pressure (bar) | Max. flow (l/min) |
|---|---|---|---|---|
| MVR1-SP/51 | Line P | NG6 | 350 | 50 |
| MVR1-SA/51 | Line A | NG6 | 350 | 50 |
| MVR1-SB/51 | Line B | NG6 | 350 | 50 |
| MVR1-ST/51 | Line T | NG6 | 350 | 50 |
| MVR1-SPT/51 | Lines P-T | NG6 | 350 | 50 |
ISO 4401-02 (NG4) modular hydraulically released check valve locking line A, B or A-B; 320 bar, 30 l/min.
ISO 4401-03 (NG6) modular check valve with flow restriction on line P; 350 bar, 50 l/min, 1 bar cracking pressure.
ISO 4401-03 (NG6) modular pilot operated check valve locking A, B or A-B; 350 bar, 50 l/min, pilot ratio 3.4:1.
ISO 4401-05 (NG10) modular check valve on line P or T; 320 bar, 100 l/min, 0.5 or 8 bar cracking pressure.