PLD20 Polaris Aluminium Gear Flow Divider
Group 2 gear flow divider: 4.8 – 32.6 cm³/rev per section, 250 bar continuous outlet pressure, max. 80 l/min inlet flow.
Product code: PLD10
Group 1 gear flow divider: 2 – 6.2 cm³/rev per section, 250 bar continuous outlet pressure, max. 35 l/min inlet flow.
PLD10 is the aluminium-body gear flow divider of the Casappa Polaris series, made of two or more sections connected by a common internal shaft. It divides the flow at a constant ratio according to section displacement and can be used as a flow equalizer, flow divider or pressure intensifier. Versions with built-in relief valves are available; 2-, 3- and 4-section combinations are standard.
| Section displacement | 2 – 6.2 cm³/rev |
|---|---|
| Max. continuous outlet pressure | 250 bar |
| Max. flow for inlet section | 35 l/min |
| Max. flow per section | 23.2 l/min |
| Body | Aluminium |
| Fluid temperature | -25 … +80 °C (NBR), -25 … +110 °C (FKM) |
| Viscosity | 12 – 100 mm²/s recommended, up to 750 mm²/s permitted |
| Type | Displacement (cm³/rev) | p1 max. continuous outlet pressure (bar) | p2 max. peak (bar) | Max. Δp between sections (bar) | Min. speed (rpm) | Max. speed (rpm) | Min. flow per section (l/min) | Max. flow per section (l/min) |
|---|---|---|---|---|---|---|---|---|
| PLD 10•2 | 2 | 250 | 280 | 200 | 1250 | 4200 | 2.65 | 8.9 |
| PLD 10•3,15 | 3.1 | 250 | 280 | 200 | 1205 | 3990 | 3.99 | 13.2 |
| PLD 10•4 | 4 | 250 | 280 | 200 | 1175 | 3840 | 4.98 | 16.2 |
| PLD 10•5 | 4.9 | 250 | 280 | 200 | 1140 | 3680 | 6.04 | 19.5 |
| PLD 10•6,3 | 6.2 | 250 | 280 | 200 | 1100 | 3500 | 7.29 | 23.2 |
| Model | Displacement (cm³/rev) |
|---|---|
| PLD 10.2 | 2.0 |
| PLD 10.3,15 | 3.1 |
| PLD 10.4 | 4.0 |
| PLD 10.5 | 4.9 |
| PLD 10.6,3 | 6.2 |
Group 2 gear flow divider: 4.8 – 32.6 cm³/rev per section, 250 bar continuous outlet pressure, max. 80 l/min inlet flow.
Magnum 30 gear flow divider: 17.2 – 81.29 cm³/rev per section, 310 bar continuous / 335 bar peak pressure.
Magnum 35 gear flow divider: 50.77 – 124.81 cm³/rev per section, 310 bar continuous / 335 bar peak pressure.