Air Treatment Units, 3 Components
- Product type
- FRL unit
- Connection
- M5 – G1
- Nominal flow
- 90 – 5000 Nl/min
Product code: PE.45.C.08.C2
Electronic pressure switch measuring -1 … +10 bar, standard analog output and 2 PNP/NPN outputs; IP65.
This electronic pressure switch measures pressures from -1 bar to +10 bar across its three versions. It comes as standard with an analog voltage or current output and two PNP or NPN outputs; the large display changes colour when the set values are exceeded.
| Product type | Pressure switch | |
|---|---|---|
| Connection | G1/8 male · M5 female | |
| Regulating range | -1 – 10 | bar |
| Gauge / switch | Digital | |
| Operating temperature | 0 … +50 | °C |
| Body material | Technopolymer | |
| Fluid | Air, non-corrosive and non-flammable gases | |
| Series / order codes | PE.45.C.08.C2, PE.45.V.08.C2, PE.45.P.08.C2, PE.45.C.08.C5, PE.45.V.08.C5, PE.45.P.08.C5, PE.45.C.08.C10, PE.45.V.08.C10, PE.45.P.08.C10, PE.45.C.10.C2, PE.45.V.10.C2, PE.45.P.10.C2, PE.45.C.10.C5, PE.45.V.10.C5, PE.45.P.10.C5, PE.45.C.10.C10, PE.45.V.10.C10, PE.45.P.10.C10, PE.45.C.11.C2, PE.45.V.11.C2, PE.45.P.11.C2, PE.45.C.11.C5, PE.45.V.11.C5, PE.45.P.11.C5, PE.45.C.11.C10, PE.45.V.11.C10, PE.45.P.11.C10, PE.45.C.12.C2, PE.45.V.12.C2, PE.45.P.12.C2, PE.45.C.12.C5, PE.45.V.12.C5, PE.45.P.12.C5, PE.45.C.12.C10, PE.45.V.12.C10, PE.45.P.12.C10, PE.45.A, PE.45.B |